Válvula de control direccional de solenoide hidráulica eterna serie DSHG


Código de modelo
| F- | DSHG | -02 | -3 | B | 2 | -E | T | -D24 | -N | AB | K | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 特殊密封 Specical Seal |
系列号 Code of Series |
公称尺寸 Nominal Size |
位数 Number of Position |
滑阀弹簧安装形式 Spool Type |
滑阀机能 Spool Function |
控制形式 Pilot Connection |
泄油形式 Drain Connection |
线圈型号 Coil Model |
接线形式 Electric Connection |
行程调整 Stroke Adjustment |
旋扭 Additional Knob |
|
| F-使用磷酸酯剂 F- Phosph- ate ester fluid |
DSHG:电液换向阀 (板式连接) DSHG: Solenoid Conterolled pilot operated directional valve (Sub-plate mounting) |
04 | 3-3位 3-Three position |
C-弹簧回中 C-Spring centred |
2,3,4,40, 60,9,10, 12 |
无-内控 E-外控None- internal pilot E-External pilot |
无-外泄 E-内泄 None- External drain E-internal drain |
AC: A110 A220DC: D12, D24AC-DC: R100 R200 |
Z6-接线盒式 None- Terminal box typeZ5-插入式 N-Plug-in ConnectorZ5L-带指 示灯的插入 N1-Plug-in Connector with indicator |
AB-两侧 A-A侧 B-B侧AB-Both side A-A side B-B side |
K-附加旋扭无-不加旋扭 K-With knob None-Without knob |
|
| 2-2位 2-Two position |
N-无弹簧 B-弹簧复位 N-No Spring B-Spring offset |
2,3,4,40 | ||||||||||
| 06 | 3-3位 3-Three position |
H-压力回中 C-弹簧回中 H-Pressure centred C-Spring centred |
2,3,4,40, 60,9,10, 12 |
|||||||||
| 10 | 2-2位 2-Two position |
N-无弹簧 B-弹簧复位 N-No Spring B-Spring offset |
2,3,4,40 | |||||||||
Dimensión


Datos técnicos
| Model | DSHG-04 | DSHG-06 | DSHG-10 | ||
|---|---|---|---|---|---|
| Max.flow rate (l/min) | 300 | 500 | 1100 | ||
| Working pressure (MPa) | A,B,P port | 31.5 | |||
| T port | External drain | 25 | |||
| Internal drain | 16(DC) 10(AC) | ||||
| Y port | External control | 16(DC) 10(AC) | |||
| Max. operating pressure (MPa) | 25 | ||||
| Weight (kgs) | Pilot valve with single solenoid |
Plug-in connector:1.5 Wire box: 1.8 | |||
| Pilot valve with double solenoids |
Plug-in connector:2.2 Wire box: 2.5 | ||||
| DHG valve | 7.3 | 16.5 | 39.5 | ||
→All Hydraulic Valve (Compele Version) PDF
Productos relacionados
→Directional Valve
→Modular Valve
→Pressure Valve
→Proportional Valve
→Flow Valve
Característica
* Estas válvulas se componen de una válvula piloto operada por solenoide y una válvula esclava operada por piloto. Cuando se energiza un solenoide, la válvula piloto dirige el flujo para mover el carrete de la válvula esclava, cambiando así la dirección del flujo en el circuito hidráulico.
* Alta presión y alto flujo. Alta presión [31,5 MPa (4570 PSI)] a lo largo de la cual el alto flujo significa un diseño de sistema compacto.
* Menor caída de presión. El ahorro de energía del sistema aumentó a medida que la caída de presión de cada válvula se redujo considerablemente